Operating speed |
0.01mm to 50cm/sec(at pin plunger) |
Operating frequency |
120 operations/min. |
Contact resistance |
25m max.(intial) |
Insulation resistance |
100M min.(at 500 VDC) |
DielectrIC strength |
1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals 2000 VAC, 50/60 Hz for 1 minute between current-carrying and non-current carrying parts and between each terminal and ground. |
Vibration |
Malfunction durability:10 to 55Hz 1.5mm double amplitude |
Shock |
Mechanical durability: 1,000m/sec2 (approx. 100Gs) Malfuncation durability:300m/sec2 (approx.30 Gs) |
Ambient operationg temperature |
Operating: -10 to + 80 |
Humidity |
95% RH max (at +20 to +35 ) |
Service life |
Mechanically: 10,000,000 operations min.(at rated OT value) Electrically: 500,000 operations min. |
Degree of protection |
IEC:IP65 |